Measurement Systems Analysis (MSA)

Following shows the MSA analysis of our bore gauge. Results show that all the MSA requirements including stability, bias, linearity, repeatability, and reproducibility are qualified. Of course, other measurement systems are also qualified to ensure our measurements are reliable.


  • Stability


msa-stability.jpg


  • Bias
msa-bias.jpg


  • Linearity
msa-linearity.jpg

  • Repeatability: %E.V. = 8.77%

  • Reproducibility: %A.V. = 4.92%

  • Gage R&R: %GR&R = 10.06%